
2V200AH OPzV Battery, GEL Tubular Plate Battery UPS EPS 5years Warranty
Basic Info Model NO.: 2V200AH Usage: UPS, Electric Power, Lighting, Electric Bicycle, Boat, Other Discharge Rate: High Discharge Rate Electrolyte: GEL Rechargeable: Chargeable Quality Standard: ISO9000, CE, RoHS, MSDS, Soncap, Coc/Voc, IEC Test Advantage 2: Hight Performance, with Low Price...
Description
Basic Info
Model NO.: 2V200AH Usage: UPS, Electric Power, Lighting, Electric Bicycle, Boat, Other
Discharge Rate: High Discharge Rate Electrolyte: GEL
Rechargeable: Chargeable Quality Standard: ISO9000, CE, RoHS, MSDS, Soncap, Coc/Voc, IEC Test
Advantage 2: Hight Performance, with Low Price Packing Quantity: 1PCS/Box
Trademark: POWER LIGHT POWER and OEM brand Origin: Guangdon, China(Mainland)
Type: Lead-Acid Batteries Nominal Voltage: 2V
Shape: Square Battery Installation: Fixed
Color: Any Color The Customer Needs Production Lead-Time: 2~30 Days After Deposit
Battery Size(mm): 206*103*390mm Specification: CE\RoHS\COC\VOC\SONCAP
HS Code: 8507200000
Product Description
Gold Light Power OPzV/GEL series is designed for alternative energy system including solar energy system with 25-year design life in float service.
Immobilized Gel and tubular plate technology is applied to provide high performance and long life.
The series is suitable for cyclic use under extreme operating conditions.
For example, telecommunication, large-scale UPS, nuclear power station, electric power substation and so on.
Product Features
·Capacity range: 200Ah-3000Ah
·Long working life: >20years
·Low self-discharge rate: ≤2%/month
·Cycle life: 100%DOD 1100times ;80%DOD 2400times;50%DOD 3200times;30%DOD 4800times
·High charge acceptance performance
·Widen operation temperature rang:- 35ºC~65ºC
·Electrolyte: Gel electrolyte used import Nano-fumed Silica special technics make it in a gel · immobilized state, more safe than AGM type, special additives makes it more stable, lower internal resistance
·Grid: made of rare earth alloy with patented formula, thicker and anti-corrosion, ensure stronger ability to recover from deep discharging
·Positive Plate: tubular type with die-casting, use quaternary alloy (Pb-Ca-Sn-Al), good corrosion resistance and long service life.
·Negative plate: improved high-density lead paste with patented design
·Separator: PVC-SiO2 separator imported from German, low internal resistance, high pore rate and long life
·Safety valve: good sensitivity, safe and reliable, equipped with flame arrester/acid filter
·Battery case: high strength ABS and durable design
·oltage class: 2V
·Float charge voltage: 2.25V-2.3V
·Equalized charge voltage: 2.4V-2.45V

GOLD LIGHT POWER AGM/GEL series is a general purpose battery with 18 years design life in float service.
With heavy duty grids, thicker plates, special additives and updated AGM/GEL valve regulated technology,
the Gold Light Power series battery provides consistent performance and long service life.
The new grid design effectively reduces the internal resistance,
which provides higher specific energy density and excellent high rate discharge characteristics.
It is suitable for communications back-up power and EPS/UPS applications .
Applications
1)Float service
2)Uninterruptible Power Supplies
3)Medical
4)Telecommunications
5)Switch Gear
6)Photovoltaic
7)Solar
8)Wind
9)Control Systems
10)Cellular Radio Stations
11)Cathodic Protection
12)Navigation Aids
13)Marine equipment
14)Electric Power Systems:example, telecommunication, large-scale UPS, nuclear power station, electric power substation and so on.
............................ect.................
Notice
Don't near the hot source and don't under the sunshine.
Don't charge in the sealed container.
No short circuit. It should be addition charge if you don't use, and single charge per three months, to avoid irreversible sulfating. The battery should be changed when the battery jar broken or the electrolyte omitted, to avoid acid corrosion.
Don't store in the space of acid gas.
You should be careful and regular check when use the battery. To avoid the battery don't work. You should change the battery if the capacity is not full or has been damage, especially after one year using.
Don't put the battery in the fire, or it will explode.
Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the electrolyte.
Don't clean the battery by using the organic solution. (e.g. petrol)
2V/12V OPzV, OPzS Series
Model | Voltage | Capacity | Dimension | Terminal | Internal Resistance | |||
10hr | Length | Width | Height | TotalHeight | ||||
OpzV2-200 | 2 | 200 | 103 | 206 | 355 | 390 | F10 | 0.6 |
OpzV2-250 | 2 | 250 | 124 | 206 | 355 | 390 | F10 | 0.57 |
OpzV2-300 | 2 | 300 | 145 | 206 | 355 | 390 | F10 | 0.55 |
OpzV2-350 | 2 | 350 | 124 | 206 | 471 | 506 | F10 | 0.42 |
OpzV2-420 | 2 | 420 | 145 | 206 | 471 | 506 | F10 | 0.38 |
OpzV2-490 | 2 | 490 | 166 | 206 | 471 | 506 | F10 | 0.35 |
OpzV2-600 | 2 | 600 | 145 | 206 | 646 | 681 | F10 | 0.33 |
OpzV2-770 | 2 | 770 | 210 | 254 | 471 | 506 | F10 | 0.31 |
OpzV2-800 | 2 | 800 | 191 | 210 | 646 | 681 | F10 | 0.3 |
OPzV2-1000 | 2 | 1000 | 233 | 210 | 646 | 681 | F10 | 0.27 |
OpzV2-1200 | 2 | 1200 | 275 | 210 | 646 | 681 | F10 | 0.25 |
OpzV2-1500 | 2 | 1500 | 275 | 210 | 796 | 831 | F10 | 0.23 |
OpzV2-2000 | 2 | 2000 | 399 | 214 | 772 | 807 | F10 | 0.22 |
OpzV2-2500 | 2 | 2500 | 487 | 212 | 772 | 807 | F10 | 0.2 |
OpzV2-3000 | 2 | 3000 | 576 | 212 | 772 | 807 | F10 | 0.19 |
OPzV12-100 | 12 | 100 | 409 | 174 | 215 | 240 | F12 | 8.00 |
OPzV12-150 | 12 | 150 | 532 | 207 | 215 | 240 | F12 | 7.00 |
OPzV12-200 | 12 | 200 | 520 | 268 | 220 | 245 | F14 | 5.00 |
Send Inquiry
You Might Also Like
-

YTX9 YT9 12V9AH AGM Sealed Maintenance Free Lead Aci...
-

2V1000AH OPzS Battery Deep Cycle Solar Power Battery...
-

2V800AH OPzS Battery Flooded Lead Acid Battery That ...
-

Lead Acid VRLA 12V 7Ah Children's Toys Electric Spra...
-

Automobile NS40Z 12V36ah Lead Acid Dry Battery and R...
-

Dry Charged Auto Battery NS40 12V32Ah High Quality C...
